A FRIESE Success Story
In August 2008 SHARP International oversaw the installation of a new set of FRIESE C-flute corrugating rolls at Krafcor of Baltimore, Maryland. Krafcor saw immediate results.
Customer: | Specialty Industries – Krafcor, Baltimore, Maryland |
Single-facer: | S&S HKE, 87″ |
Flute: | C |
Combined board samples were taken prior to and after installation of the new corrugating rolls.
The same rolls of linerboard and medium were quarantined and used for the before and after combined board samples.
Property |
Unit |
Before (old corrugating rolls) |
After (new FRIESE rolls) |
|
---|---|---|---|---|
corrugating roll diameter | mm | 304.5 / 304.5 | 304.5 / 304.5 | |
fluting height | mm | 3.63 | 3.50 | |
pitch | mm | 7.940 | 7.940 | |
number of teeth | % | 120 | 120 | |
tension factor | 100.0 | 89.7 | ||
tension | 5.85 | 5.25 | ||
take-up factor | 1.422 | 1.386 | ||
medium savings | % | – | 2.1 | very quick ROI |
Mechanical Strength | ||||
ECT – operator side | % | 100.0 | 102.4 | 2.4% increase |
ECT – drive side | % | 100.0 | 102.3 | 2.3% increase |
Combined board testing conducted by Gary White / Toledo Forest Product Laboratories, Inc.
Combined board samples supervised by Ralph Young / Alternative Paper Solutions